Instruments

Title Cover Content Actions
JEOL JEM 2100 PLUS
Reservable
Japan JEOL JEM 2100PLUS
 1. Accelerating voltage: 80 – 200 kV 
 2. Lamp silk: LaB6 
 3. Resolving power: point image 0.27 nm 
 4. Magnification: 1,000 – 1,000,000 
 5. Image capture: CCD-Camera(Gatan OneView)
 6. EDS (OXFORD X-MAX )
 7. Shot Meister application (JEOL JEM-2100 Plus)

Charging method
JEOL JEM-2100PLUS   
Fee Items                                CGU Labs                /   Non CGU Labs 
cryoEM or with EDX            1500 NT (hour)         /   not open 
TEM only                              1200  NT (hour)         /   not open
 
Info
Reserve
JEOL JEM 1230
Reservable
Japan JEOL JEM-1230
 1. Accelerating voltage: 40 – 120 kV 
 2. Lamp silk: LaB6 
 3. Resolving power: point image 0.36nm 
 4. Magnification: 1,200 – 600,000 
 5. Image capture: CCD-Camera(Gatan SC1000W) 

Charging method
 JEOL JEM-1230    
CGU Labs / Non CGU Labs 
300 NT (hour) /  600 NT (hour) 

Info
Reserve
ZEISS LSM780
Reservable
Germany ZEISS LSM780
1. Diode Laser:405 nm 30mW 
2. CW Laser:440 nm 15mW 
3. Multiline Argon-Laser:458/488/514 nm 25mW 
4. DPSS Laser:561 nm 20mW 
5.  HeNe Laser:633 nm 5mW

 Charging method
 ZEISS LSM780
 CGU Labs / Non CGU Labs 
 650 NT (hour) / 1300 NT (hour)

Info
Reserve
ZEISS LSM510META NLO
Reservable
Germany ZEISS LSM510META NLO
1. Mai-Tai HP laser(Spectra-Physics):690-1020 nm  
2. CW Laser:440 nm 15mW 
3. Multiline Argon-Laser:458/477/488/514 nm 30mW 
4. DPSS Laser:561 nm 10mW 
5.  HeNe Laser:633 nm 5mW

  
   Charging method
   ZEISS LSM510 NLO
   CGU Labs / Non CGU Labs 
   500 NT (hour) / 1000 NT (hour)
  
Info
Reserve
HITACHI S-3000N
Reservable
Japan HITACHI S-3000N
1.  Accelerating voltage: 0.3 - 30 kV 
2. Lamp silk: Tungsten wire 
3. Resolving power: 3.0 nm 
4. Magnification: 15 – 300,000 
5. Image capture: CCD-Camera 
6. EDS (EMAX Evolution X-Max) 

 
Charging method
HITACHI S-3000N
CGU Labs / Non CGU Labs
300 NT (hour) / 600 NT (hour)

Specimen Preparation Requirements:

  1. Please place the sample on an aluminum stub with a diameter of 26 mm.
  2. To maintain vacuum integrity, the sample must not decompose, release gas, or become liquid under electron beam exposure.
  3. To prevent damage, this instrument will not accept powder samples or materials that are strongly magnetic, magnetic (e.g., iron, cobalt, nickel), or easily attracted by the electromagnetic lens.
  4. To avoid damage, this instrument will not accept samples that are toxic, corrosive, volatile, or have a low melting point.
  5. To prevent computer contamination, please use a CD for burning electronic files.

  
Info
Reserve
JEOL JSM-7500F
Reservable
Japan JEOL JSM-7500F
1. Accelerating voltage: 0.3 - 30 kV 
2. Lamp silk: W(310) cold field emission 
3. Resolving power: 1.0 nm 
4. Magnification: 25 – 1,000,000 
5. Image capture: CCD-Camera 
6. EDS (OXFORD INCA X-ACT)
7. Deben Centaurus Backscatter Detector. 

Charging method
JEOL JSM-7500F
Fee Items                                       CGU Labs       /     Non CGU Labs 
Unused EDS                              800 NT (hour)    /     1600 NT (hour)
Use EDS                                   1000 NT (hour)    /     2000 NT (hour) 

Specimen Preparation Requirements:

  1. Please place the sample on an aluminum stub with a diameter of 26 mm.
  2. To maintain vacuum integrity, the sample must not decompose, release gas, or become liquid under electron beam exposure.
  3. To prevent damage, this instrument will not accept powder samples or materials that are strongly magnetic, magnetic (e.g., iron, cobalt, nickel), or easily attracted by the electromagnetic lens.
  4. To avoid damage, this instrument will not accept samples that are toxic, corrosive, volatile, or have a low melting point.
  5. To prevent computer contamination, please use a CD for burning electronic files.
Info
Reserve
3D Cell Explorer
Reservable
Nanolive 3D Cell Explorer, Switzerland
a. Illumination Source:Class 1 low power laser;λ=520nm, sample exposure 0.2 mW/mm2
b. Resolution:Δx,y = 200 nm;Δz = 400 nm
c. Field-of-view:90 x 90 x 30 um
d. Objective:Dry objective;60 x magnification / NA 0.8
e. Camera: CMOS Sony IMX174 sensor
f. Heating and Incubation System

Charging method
3D Cell Explorer
CGU Labs / Non CGU Labs 
150 NT (hour) / 300 NT (hour)
  
Note: A period of less than half an hour counts as half-hour session. 
           You will not be charged for any extended session of previous users. 
Info
Reserve
AXIO IMAGER M2
Reservable
ZEISS AXIO IMAGER M2, Germany
a. 6-position objective nosepiece HD DIC M27 mot.                  
b. Objective 5X, 10X, 20X, 40X, 63X, 100X.
c. Camera Adapter 60N-C 1" 1x
d. Joystick XY; CAN (D)
e. Mechanical stage 75x50 mot; CAN (D)
f. X-Cite 120LED System with adapter
g. Camera Adapter 60N-C 1" 1x
h. Microscopy Camera Axiocam 512 color (D)

Charging method
ZEISS AXIO IMAGER M2
CGU Labs / Non CGU Labs 
150 NT (hour) / 300 NT (hour)
  
Note: A period of less than half an hour counts as half-hour session. 
           You will not be charged for any extended session of previous users. 
Info
Reserve
ULTRACUT E
Reservable
Charging method
ULTRACUT E
CGU Labs / Non CGU Labs 
30 NT (hour) / 60 NT (hour)
  
Note: A period of less than half an hour counts as half-hour session. 
          You will not be charged for any extended session of previous users. 
Info
Reserve
ULTRACUT S
Reservable
ULTRACUT S 
Info
Reserve
LEICA EM UC7
Reservable
Charging method
LEICA EM UC7
 CGU Labs / Non CGU Labs 
 50 NT (hour) / 100 NT (hour)
   
 Note: A period of less than half an hour counts as half-hour session. 
           You will not be charged for any extended session of previous users. 
Info
Reserve
MICROM
Reservable
CGU Labs / Non CGU Labs 
 0 NT (hour) / 0 NT (hour)
Info
Reserve
LEICA CM 3050S
Reservable
Charging method
 LEICA CM 3050S
 CGU Labs / Non CGU Labs 
 0 NT (hour) /  0 NT (hour)
Info
Reserve
LEICA EM CPD 300
Reservable
Charging method
 LEICA EM CPD 300
 CGU Labs / Non CGU Labs 
 200 NT (hour) / 400 NT (hour)
   
 Note: A period of less than half an hour counts as half-hour session. 
           You will not be charged for any extended session of previous users. 
Info
Reserve
集中管理
Reservable Entrusted
Info
Reserve
LEICA EM UC6
Reservable
Charging method
LEICA EM UC6
CGU Labs 
100 NT (hour) 
   
 Note: A period of less than half an hour counts as half-hour session. 
           You will not be charged for any extended session of previous users. 
Info
Reserve
LEICA STELLARIS8
Reservable
Germany  LEICA STELLARIS8 
 1. Diode Laser:405 nm 50mW
 2. White light laser system, pulsed laser 440nm-790nm, 1nm adjustable, 351 lines. 
 3. TauSense(TauContrast,TauGating,TauSeperation)
 4. Power HyD-S (3 set), Power HyD-X (1 set) 
 5. Falcon FLIM application
 6. Lightning confocal superresolution
 7. LAS X Navigator application  
  
   Charging method
   LEICA STELLARIS8 
   CGU Labs / Non CGU Labs 
   850 NT (hour) / 1700 NT (hour)

   The charging principle for long-term observation of live cells is as follows:
   For reservations spanning from 8:00 PM on the current day to 8:00 AM the next day,
   if the total duration is 5 hours or more, the charge is 500 yuan per hour. 
  
Info
Reserve
Per page 10 20 | Total 17